In short: Wall insulation is work carried out to limit the passage of heat, sound or water through a wall. On an external wall, thermal insulation is done in three ways: from the outside (ETICS or a curtain wall), from the inside, or by building the wall with blocks that have an insulation layer. In walls between dwellings and partition walls sound insulation comes to the fore, and on a below-grade basement wall waterproofing and thermal insulation.
This guide explains which insulation is needed for each type of wall, how insulation from the outside, from the inside and with blocks differ, and how each method is applied. For the insulation work in the whole building see our guide to building insulation, and for the material groups our guide to insulation materials.
What is wall insulation and which walls is it applied to?
Wall insulation is not a single application: it is done with different materials to limit heat loss in an external wall, sound in a wall between dwellings and water in a wall below ground. According to İZODER, for energy efficiency all heat-losing infill walls and elements such as columns, beams, lintels and tie beams should be insulated.
| Type of wall | Main insulation | Method | Detailed guide |
|---|---|---|---|
| External wall | Thermal; reaction to fire class on the facade | ETICS, curtain wall, internal insulation or blocks with an insulation layer | what is ETICS |
| Wall between dwellings | Sound; thermal resistance of at least 0.80 m²K/W | Sound insulation block or a sound insulation panel on the face of the wall | wall sound insulation |
| Partition wall within a dwelling | Sound | Stone wool board between the studs of a lightweight partition | stone wool sound insulation |
| Wall adjoining a stairwell or lift shaft | Sound, thermal | Insulation panel on the dwelling side of the wall | internal wall insulation |
| Below-grade basement wall | Water, thermal | Waterproofing on the face exposed to water, with XPS board over it | foundation and basement wall insulation |
Source: Regulation on Energy Performance of Buildings, Article 9; Regulation on the Protection of Buildings against Noise; Regulation on Waterproofing in Buildings. The table is general guidance.
By which methods is an external wall thermally insulated?
An external wall is insulated by three methods: from the outside, from the inside or within the body of the wall. İZODER states that insulation in walls can be done from the outside of the building, from the inside or between two wall leaves. The table below compares the three methods.
| Criterion | External insulation (ETICS) | Internal insulation | Blocks with an insulation layer |
|---|---|---|---|
| Position of the insulation | Outer face of the wall | Room-side face of the wall | Inside the block; put in place as the wall is built |
| Thermal bridges | Columns, beams and slab edges are covered as well | Thermal bridges remain at junctions with internal walls, floors and ceilings | Column and beam faces are insulated separately |
| Position of the existing wall | Stays on the warm side of the insulation | Stays on the cold side of the insulation; moisture control gains importance | The insulation is part of the wall |
| Where it is applied | New and existing buildings; usually the whole building | A building whose facade cannot be touched, or a single dwelling | A new building whose walls have not yet been built |
| Room area | Unchanged | Reduced by the thickness of the panel | The wall thickness is determined in the design |
| Mega product | Stone Wool ETICS Board, EPS boards, board adhesive and base coat | DesiWool | MegaBlock Thermal; MegaBlock BC on reinforced concrete faces |
According to İZODER, in an external application no thermal bridges form because insulation material can be fixed to the whole facade; and because the wall stays warm, condensation does not occur either. We explained what a thermal bridge is in our article on the thermal bridge.
How is a wall insulated from the outside?
Insulating a wall from the outside is most commonly done with ETICS: the boards are bonded and anchored to the wall, covered with a mesh-reinforced base coat and finished with a finishing coat. With the times and values in Mega’s data sheets, the order is as follows:
- The surface is prepared. The wall must be clean, cured and sound; the starter track is fixed level.
- The boards are bonded. Board adhesive MTA-3333 is consumed at 3–5 kg per m²; the boards are laid in a staggered pattern so that the joints do not line up.
- They are anchored. The anchors are driven at least 24 hours after bonding.
- The mesh-reinforced base coat is applied. Two days after bonding, base coat MTP-3344 is applied; the 160 g/m² alkali-resistant mesh is embedded in the base coat with a 10 cm overlap.
- The finishing coat is applied. The decorative mineral render is applied 2 mm thick and painted after it dries.
The choice of board is governed by the thermal insulation design and by the reaction to fire requirement, which depends on building height; you can find the system with stone wool boards in our guide to stone wool ETICS and the details of the steps in our article how ETICS is applied. In buildings where the facade cladding is hung on a supporting frame, the insulation is placed behind the cladding in the way we explained in our article on curtain wall insulation.
How is a wall insulated from the inside?
A wall is insulated from the inside by fixing an insulation panel to the room-side face of the external wall. First any moisture problem in the wall is dealt with; then the surface is prepared, the panel is fixed without leaving an air gap, the joints are closed and the surface is made ready for painting.
- Check the wall. If there is damp, blistering plaster, mould or a leak, the source is dealt with first and the wall is left to dry out. A damp wall is not covered over.
- Prepare the surface. Loose plaster, old wallpaper, dust and dirt are removed; cracks and hollows are repaired.
- Plan the services. Sockets, switches, radiators and pipe penetrations are marked before installation.
- Fix the panel. With a composite panel such as DesiWool the stone wool face goes against the wall and the gypsum board face towards the room. No air pocket must remain between the panel and the wall. The UK government’s guide to internal wall insulation identifies dab bonding that leaves a gap behind as the method with the highest risk of condensation.
- Seal the junctions. No gaps are left between panels or at the junctions with the ceiling, floor and side walls.
- Finish the surface. The joints are closed with tape and filler; the surface is finished with primer and paint.
For this application Mega’s DesiWool panel is a composite panel with gypsum board on one face and stone wool on the other. According to its technical data sheet it measures 2700 x 1200 mm and is offered in six thicknesses between 15 and 80 mm; the declared thermal conductivity is no more than 0.035 W/mK and the thermal resistance is 0.40 for 15 mm, 1.40 for 50 mm and 2.25 m²K/W for 80 mm. The application details are in our guide to internal wall insulation.
With internal insulation the existing wall stays on the cold side of the insulation, so the condensation risk is assessed separately. The DesiWool data sheet does not define a separate vapour control layer; whether an additional one is needed is determined from the wall build-up by a condensation calculation, and if one is used it goes on the room side, that is the warm side, of the insulation. According to the UK government’s guide to internal wall insulation, thermal bridges form where internal walls and intermediate floors meet the external wall; these bridges are reduced with details such as returning the insulation a short way along the adjoining surface. To tell the source of moisture apart, see our articles what is condensation and what causes mould on walls.

How is wall insulation solved with insulated blocks?
With a block that has an insulation layer, the thermal insulation comes inside the block and is put in place as the wall is built. Mega’s MegaBlock Thermal block consists of layers of pumice, cement and stone wool; the technical data sheets give the thermal value for the finished wall, not for a single block.
| Series | Block thickness (mm) | U-value of the wall, unplastered (W/m²K) | U-value of the wall, plastered (W/m²K) |
|---|---|---|---|
| MegaBlock Thermal 145/50SW | 145 | 0.49 | 0.36 |
| MegaBlock Thermal 195/90SW | 195 | 0.35 | 0.28 |
| MegaBlock Thermal 245 series | 245 | 0.32 | 0.26 |
| MegaBlock Thermal 295 series | 295 | 0.21 | 0.19 |
Source: MegaBlock Thermal technical data sheets. The plastered values are for a wall with 3 cm of gypsum plaster inside and 3 cm of thermal render outside. The wall λ in the data sheets equals the design value in the TSE National Technical Approval documents for an unplastered wall laid with 3 mm mortar of 900 kg/m³ density; with thicker joints the U-value of the wall is higher than in the table. For the 245 and 295 mm series the data sheet gives one value for two stone wool layouts. The smaller the U-value, the less heat the wall lets through; whether the chosen series is sufficient and whether the wall needs additional insulation is determined by the calculation in the thermal insulation design.
In a wall built with blocks, reinforced concrete faces such as columns, beams and slab edges are insulated separately. According to the method in Mega’s product catalogue, MegaBlock Thermal is laid projecting at least 6 cm outwards in walls facing the outside, and MegaBlock BC is bonded to the reinforced concrete faces. According to its product page, MegaBlock BC is stone wool with a density of 150 kg/m³ coated with acrylic render. You can find a comparison of the two solutions in our article thermal insulation block or ETICS.

How is sound insulation done in a wall?
Sound insulation in a wall is done to reduce the passage of airborne sounds such as speech and music to the neighbouring room. The Regulation on the Protection of Buildings against Noise requires at least acoustic performance class C in new buildings. The solution depends on whether the wall is new or existing.
| Situation | Solution | Mega product | Value in the data sheet or test report |
|---|---|---|---|
| Newly built wall between dwellings | Sound insulation block with stone wool layers | MegaBlock Acoustic | In the TSE test named in the data sheet heading, unplastered wall: 41.60 dB for 145/50SW, 47.60 dB for the 245 series and 48.70 dB for the 295 series; in the data sheet table, plastered wall R’w 47, 56 (-1;-3) and 60 dB |
| Lightweight partition wall | Stone wool board between the studs | Partition Board (MEGA SW PB 40/50/60) | A1; λD ≤0.035 W/mK; 40–120 mm |
| Existing party wall or internal wall | Stone wool and gypsum board composite panel on the face of the wall | DesiWool | W15: in the laboratory R’w 29 dB on one side, 42 dB on both sides |
Source: Mega technical data sheets; DesiWool W15 test reports (Ticem). The values were not measured under equivalent conditions and are not to be read as a gain added to the value of an existing wall.
Sound passes through the weakest point of the insulation: an open socket recess or a gap where the wall meets the ceiling lowers the result. The details of the methods are in our guides to wall sound insulation and sound insulation. Impact sound is dealt with in the floor, not in the wall; we explain the layers in our guide to floor insulation.
How is a below-grade basement wall insulated?
On a below-grade basement wall, waterproofing is done first and thermal insulation second: the waterproofing is the layer closest to the concrete, and the XPS board stays outside it and protects the waterproofing during backfilling. The Regulation on Waterproofing in Buildings is based on applying waterproofing in new buildings from the side of the building element that is exposed to water.
According to İZODER’s application document, in this detail the thermal insulation boards are placed in a staggered pattern so that no open joints form at the butt ends; anchors are not used in fixing the boards so that the waterproofing is not pierced, and the backfill is placed in stages. The boards are spot-bonded with an adhesive compatible with the waterproofing. For this detail İZODER describes XPS boards with a compressive strength of at least 300 kPa, skins on both faces and rebated edges; among Mega’s XPS types the 300 kPa one is MEGA XPS T3000, and the type is selected in the design. In Mega’s XPS data sheets the long-term water absorption by total immersion is no more than 0.7%. The whole layer order is in our article on foundation and basement wall insulation.
What do the fire rules require in wall insulation?
The Regulation on Fire Protection of Buildings ties the reaction to fire class of the insulation material in a wall to requirements that depend on where the wall is.
- External facade: In buildings with a building height of more than 28.50 m the external facade must be of limited-combustibility material, and in other buildings of at least low-flammability material (Article 27).
- ETICS: The system consisting of board, adhesive, anchor, render mesh and render is certified as a system by an accredited laboratory.
- Internal surfaces: Thermal and sound insulation applied internally on walls is made of at least normally flammable material, and in high-rise buildings and halls with a capacity of more than 100 people of at least low-flammability material (Article 29).
In Mega’s data sheets stone wool boards are class A1, DesiWool is A1-s1-d0, and EPS and XPS boards are class E. You can find what the classes mean in our article on the fire class of insulation materials.
What are the common mistakes in wall insulation?
Most mistakes stem from not choosing the method to suit the condition of the wall and from skipping junction details.
- Covering a damp or leaking wall from the inside without dealing with the source.
- With internal insulation, dab bonding the panel and leaving an air gap behind it.
- With external insulation, leaving columns, beams and window reveals uninsulated.
- In a block wall, moving on to plastering without insulating the reinforced concrete faces.
- In sound insulation, leaving gaps at sockets, services and the ceiling junction open.
- Choosing the thickness without calculation. The thickness of the insulation on an external wall is determined in the thermal insulation design.
Application note from MegaUsta: With internal insulation, keep the hole you cut in the panel for a socket box as tight as the size of the box and fill the remaining gap. Both heat and sound find the weakest point; a single gap left open can lower the performance of the whole wall.
Frequently Asked Questions
How is a wall insulated?
A wall is insulated in one of three ways depending on the type of wall. On an external wall, thermal insulation boards are applied to the outer face with a rendered system (ETICS), added to the inner face as panels, or the wall is built with blocks that have an insulation layer. In walls between dwellings and partition walls the aim is sound insulation. On a below-grade basement wall, waterproofing comes first and the thermal insulation board is placed over it.
Should a wall be insulated from the inside or the outside?
If a decision can be taken for the whole building, insulation from the outside gives a more comprehensive result. According to İZODER, because the whole facade is covered in an external application, no thermal bridges form, the wall stays warm and condensation does not occur. Insulation from the inside is applied where the external facade cannot be touched or a single dwelling is being insulated; with this method the thermal bridges at junctions and moisture are dealt with separately.
Does wall insulation prevent mould?
If the cause of the mould is moisture condensing on a cold surface, insulating the wall from the outside reduces the risk: ETICS raises the temperature of the inner surface. If the moisture comes from a leak or from the ground, insulation does not solve the problem; the source is dealt with first. With internal insulation a damp wall is not covered over and no air gap is left between the panel and the wall. Regular ventilation also lowers indoor humidity.
Which material is used for wall insulation?
On an external wall, stone wool, EPS or XPS board is used in rendered systems, and stone wool board in curtain walls. On the inner face of the wall, composite panels such as DesiWool, made of stone wool and gypsum board, are preferred, and in lightweight partition walls the stone wool partition board placed between the studs. If the insulation is to be solved within the body of the wall, MegaBlock blocks with stone wool layers are used, and XPS board on a below-grade basement wall.
How is a party wall soundproofed?
On an existing party wall, sound insulation is done by adding a sound insulation panel to the room side of the wall. In laboratory tests with DesiWool W15, R’w 29 dB was measured for application on one side and 42 dB for application on both sides; these values are not to be read as a gain added to an existing wall. If socket and service openings are not sealed, sound continues to pass through these points. In a new building the wall can be built with sound insulation blocks.
How thick should wall insulation be?
The thickness of the thermal insulation on an external wall is calculated in the thermal insulation design prepared in accordance with TS 825; the climate zone, the material of the wall and the λD value of the board determine the result. In Mega’s data sheets the thermal resistance of MEGA SW F150 stone wool ETICS board is 2.70 m²K/W for 100 mm, and that of the DesiWool panel 1.40 m²K/W for 50 mm. For a wall between dwellings the Regulation on Energy Performance of Buildings (Article 9) requires a thermal resistance of at least 0.80 m²K/W.
Sources
- İZODER: Thermal insulation, general information (thermal insulation in walls; in Turkish)
- İZODER: Thermal insulation of below-grade external walls and foundations (PDF, in Turkish)
- Regulation on Energy Performance of Buildings, current text, Articles 9 and 10 (Legislation Information System; in Turkish)
- Regulation on Fire Protection of Buildings, Articles 27 and 29 (Legislation Information System; in Turkish)
- Regulation on the Protection of Buildings against Noise, Official Gazette, 31.05.2017, No. 30082 (in Turkish)
- Regulation on Waterproofing in Buildings, Official Gazette, 27.10.2017, No. 30223 (in Turkish)
- GOV.UK: Retrofit Internal Wall Insulation, Guide to Best Practice (2021)
- Mega technical data sheet: MEGA SW F150 ETICS Board (PDF, in Turkish)
- MegaTech MTA-3333 Thermal Insulation Board Adhesive technical data sheet (PDF, in Turkish)
- MegaTech MTP-3344 Thermal Insulation Board Base Coat technical data sheet (PDF, in Turkish)
- Mega technical data sheet: DesiWool (PDF)
- DesiWool W15 test report, one side (PDF)
- DesiWool W15 test report, both sides (PDF)
- Mega technical data sheet: Partition Board (PDF, in Turkish)
- Mega technical data sheet: MegaBlock Thermal 145/50SW (image, in Turkish)
- Mega technical data sheet: MegaBlock Thermal 195/90SW (image, in Turkish)
- Mega technical data sheet: MegaBlock Thermal 245 series (image, in Turkish)
- Mega technical data sheet: MegaBlock Thermal 295 series (image, in Turkish)
- Mega technical data sheet: MegaBlock Acoustic 145/50SW (image, in Turkish)
- Mega technical data sheet: MegaBlock Acoustic 245 series (image, in Turkish)
- Mega technical data sheet: MegaBlock Acoustic 295 series (image, in Turkish)
- Mega technical data sheet: MEGA XPS T3000 (PDF, in Turkish)
You can review the product groups offered for walls on our insulation products page and contact us through our contact page with questions about your project.