XPS - Rough Channel Board

Type 1500 (150 kPa) Type 2000 (200 kPa)
Type 2500 (250 kPa) Type 3000 (300 kPa)

Mega Insulation Solutions  Rough and Rough Channelled Surface XPS Boards; As a result of the processing of polystyrene raw material by extrusion, the edge shape is produced with lamp bin and the surface shape with rough or rough-channel. Mega Insulation XPS; It can provide high adherence where it is applied with its surface shape and eliminating heat bridges with its edge shape. Mega Insulation  XPS, which provides thermal insulation at a maximum level with its low thermal conductivity value, does not dissipate or crumble with its high compressive strength.

Usage Areas

  • Mega Insulation Rough Chanelled Surfaces are used in the contact facade system and internal insulation system, which are used to insulate the buildings from the outside or inside,
  • Under the roof and overhang,
  • Parking ceilings,
  • Columns and beams (for thermal insulation purposes),
  • In foundations and columns,
  • Used in all kinds of prefabricated composite systems and double walls.
  • Stock and Storage Conditions
  • Mega Insulation thermal insulation boards must be protected from sunlight when long term storage is required.
  • If the Mega Insulation thermal insulation boards are exposed to sunli- ght for a long time, it may be observed that their surface and size deteriorates.
  • During the production of Mega Insulation thermal insulation boards, they are produced by using fire preventive additives.
  • Megaboard thermal insulation boards should not be used with solvent materials.
  • It should be paid attention to horizontal stacking. If stacked verti- cally, edges may lose their linearity and be damaged.
  • Insulation boards can be applied to the underground exterior wall with self-adhesive bituminous sheets on both sides.
  • At the level where thermal insulation ends at the basement level, the finishing detail that prevents water intake and separation of the boards should be applied behind the waterproofing system.
  • Drainage system should be installed in a way to prevent positive water pressure.
  • It should prevent the insulation boards from slipping during the compaction of the backfill. For this purpose, the insulation boards should be placed on a solid and stable plane.
  • In thermal insulation applications made on waterproofing memb-ranes, it is important not to pierce the waterproofing blanket. Therefore, thermal insulation layers should not be applied on wa- terproofing membranes using anchors.